Stramit® Metallic Monopanel® Cladding

Features

  • 250mm Cover – allows for quick installation.
  • Simple Installation – "fix, hinge and cover and fix again" procedure.
  • Versatility – can be used in either vertical, diagonal or horizontal applications.
  • Secret Fixing – fasteners are concealed from view to give a smooth appearance.
  • Trims – a complete range of trims and accessories are available.
  • Continuous Interlock – to weatherseal all joints.
  • High Tensile Steel – for greater damage resistance and performance.


    Accessories

    A range of flashings, trims and moulds are available for use with Stramit Monopanel® wall cladding. Starter clips (P3) are also available.


    Material

    Stramit Monopanel® wall cladding is a cold roll formed steel product in G550 base material (550 MPa minimum yield stress) with zinc-aluminium alloy substrate in accordance with AS1397 and colour coating available in a range of colours.

    STRAMIT MONOPANEL® WALL CLADDING - SHEETING MASS (kg/m2 of roof area)
    thickness BMT Zincalume® Colorbond®
    0.48mm 4.51 4.58



  • Pressures
     
    STRAMIT MONOPANEL® WALL CLADDING – SERVICEABILITY LIMIT STATE CAPACITY
    span
    type
    pressure (kPa) at the spans (mm) shown
    600 900 1200 1500 1800 2100 2400 2700
    internal 4.57 3.06 2.30 1.84 1.54 1.32 1.15 1.02
    equal 4.57 3.06 2.30 1.84 1.54 1.32 1.15 1.02
    double 5.19 3.47 2.61 2.09 1.74 1.49 1.31 1.16

    STRAMIT MONOPANEL® WALL CLADDING – STRENGTH LIMIT STATE CAPACITY
    span
    type
    pressure (kPa) at the spans (mm) shown
    600 900 1200 1500 1800 2100 2400 2700
    internal 7.29 4.46 3.19 2.48 2.03 1.72 1.49 1.31
    equal 7.29 4.46 3.19 2.48 2.03 1.72 1.49 1.31
    double 8.17 5.00 3.58 2.78 2.28 1.92 1.67 1.47
    Tables are based on testing to AS1562 and AS4040 parts 0, 2 and 3. Internal spans must have both end spans 20% shorter.Values only valid for use with steel support members of 0.75mm or thicker.


    Impact  

    For wall areas likely to be subject to human impact, sheeting spans should be reduced. Impact loads will vary considerably and these are not prescribed in Australian Standards. A maximum span of 1200mm is suggested for such areas, but this should be adjusted dependent upon the exposure and importance of the application.


    Installation

    All fasteners should conform to AS3566 – Class 3 and be completely compatible with the cladding material used. 

      For steel
    - No. 10 x 16mm wafer head self-drilling, self-tapping screws.
    - 3.2mm aluminium rivet.
      For timber
    - No. 10 x 25mm (35mm for softwood) wafer head self-drilling type 17 screws.



    Fastener Positions 

    Use one fastener per sheet at each support placed in the pre-punched slots.



    For further installation information see the section later in this manual.